Recently Viewed

Alerta Sapphire Replacement Alternating Air Mattress System

  • Suitable for patients at high risk of pressure ulcers
  • Nylon TPU coated, micro-perforated air cells
  • Self-inflating 2 inch sealed foam base
  • Constant auto pressure sensing with SensaCare Truflo

Availability:  

Usually delivered in 3 - 5 working days  

Usually delivered in 3 - 5 working days

Our Price:  £457.00 (exc VAT)
(£548.40 Inc. VAT) (inc 20% VAT)
Earn 457 Loyalty Points
+

Brand:  Alerta Medical
Pressure Relief Level:  High Risk


Alerta Sapphire Replacement Overlay Alternating Air Mattress System

For care providers and family, the battle against pressure ulcers developing on your patients or loved ones is constant, difficult and stressful. Therefore, effective pressure care is a top priority, as excessive pressure or pressure mismanagement is a recipe for disaster. To achieve this, the appropriate alternating Air Mattress or cushioning system is crucial, as it can provide peace of mind for the carer, and better quality of life for the patient.

Luckily, the Alerta Sapphire Replacement Overlay Alternating Air Mattress System was designed to be an affordable and reliable solution. This air mattress system is the perfect tool to prevent and treat pressure ulcers in high risk patients in hospital, nursing and care home environments.

Easy to Use and Effective

The Alerta Sapphire Replacement Overlay Alternating Air Mattress System features 5" air cells and a self-inflating 2" sealed foam base so that comfort, as well as prevention and treatment of ulcers, is ensured. With simple to use settings and functionality, including an auto-firm function, visual warnings for air loss and remote control, the Alerta Sapphire makes it easy for any care provider to quickly set up the air mattress system, and have it operating at the perfect pressure within seconds.

Equipped with micro-perforation technology, Nylon TPU coated air cells for durability and a pillow function for comfort, the Sapphire is the solution for low-cost, high risk patient care.

Constant Pressure Regulation

The Alerta Sapphire incorporates cutting edge SensaCare Technology, which provides constant automatic pressure sensing with an air sensor and microcomputer regulator, to provide consistent ultra-low interface pressure. This promotes an even ambience for natural sleep patterns and stable blood circulation, and together with the Ultra Silent pump, makes for optimal sleeping conditions for both comfort and ulcer prevention. 

Multi-Stretch, Water Resistant Cover

To improve durability and quality of care, this alternating Air Mattress system is fitted with a multi stretch and waterproof cover. This vapour permeable PU cover is anti-microbial, to reduce bacteria and odour, and fully machine-washable so that you can keep your patient's environment sanitary at all times. 

Is This Product Tested for Fire Safety?

Yes, all components of Alerta's pressure relief products are tested to comply with Crib 5 fire safety regulations. This means that all foam, air cells and covers for Alerta mattresses and cushions are tested to the most stringent fire safety guidelines, ensuring you stay fully compliant and up to date with regulations.

Key Features

  • Suitable for patients at high risk of developing pressure ulcers
  • Nylon TPU coated, micro-perforated air cells
  • Includes a 2" self-inflating sealed foam base
  • Cells are branded and independently removable
  • Pillow function for comfort
  • Zipped storage bag
  • CPR release
  • Multi-stretch, waterproof cover
  • Cover is anti-microbial and machine washable
  • Features a 360-degree zipper
  • Ultra-silent pump
  • Robust pump connection
  • Transport mode for easy travel
  • Remote control for added cycle control

Specifications

Air Mattress

  • Dimensions: 200 x 90 x 18cm
  • Air Mattress Weight: 10kg
  • Cell Structure: Cell-on-cell foam
  • CPR: Quick release toggle

Pump

  • Operating System: Sensacare Truflo Technology
  • Dimensions (L x W x D): 29 x 12 x 10cm
  • Weight: 4kg
  • Max load: 150kg
  • Cycle Time: 6, 9, 12, 25 minutes
  • Air Output: 6-8 litres/minute
  • Power input: AC220 - 240V, 50Hz
  • Power Consumption: 7W
  • Pressure Range: 30 - 120mmHg
  • Fitted with hanging brackets

Cover

  • Multi-stretch PU
  • Vapour permeable
  • Water resistant
  • Machine washable
  • Antimicrobial
  • Features a 360-degree zipper
  • White underside of cover

See Alerta for Yourself

This Item Is Not Returnable On Grounds Of Hygiene

Please note, Medical Supplies is dedicated to maintaining the highest levels of hygiene for all of its products and for this reason this item is non-refundable and non-returnable if unsuitable or unwanted on grounds of hygiene.

If you have any questions regarding this returns policy, please contact our Medical Supplies Customer Care Team on 020 7501 0593 for further details.

Customer Reviews

Be the first to Write a Review for this item!

Related Products
Alerta Ruby 2 Alternating Air Mattress Replacement System

Alerta Ruby 2 Alternating Air Mattress Replacement System

no rating
  • Suitable for patients at very high risk of developing pressure ulcers
  • Ideal for patient care in care homes and residential care settings
  • SensaCare Truflo Technology provides constant auto pressure sensing
  • Promotes natural sleep patterns with Ultra-Silent pump operation
£592.99 (exc VAT)
£711.59 (inc VAT)
Usually delivered in 3 - 5 working days  Usually delivered in 3 - 5 working days
Details

Remote Control for the Alerta Ruby 2 Alternating Air Mattress Replacement System

Remote Control for the Alerta Ruby 2 Alternating Air Mattress Replacement System

no rating
  • Spare remote for the Alerta Ruby 2 Mattress System
  • Ideal as a replacement for damaged/faulty remote controls
  • Provides a user-friendly way to operate your mattress system
  • Recommended for carers or independent users
£23.33 (exc VAT)
£28.00 (inc VAT)
Usually delivered in 3 - 5 working days  Usually delivered in 3 - 5 working days
Details

Replacement Mattress Pad for the Alerta Bubble 2 Overlay Alternating Air Mattress System

Replacement Mattress Pad for the Alerta Bubble 2 Overlay Alternating Air Mattress System

no rating
  • Replacement mattress pad only, supplied without a pump
  • Spare part for the Alerta Bubble Overlay Mattress System
  • Includes tuck-in extension flaps for easier use
  • Made with antimicrobial material to prevent infection
£43.77 (exc VAT)
£52.52 (inc VAT)
Usually delivered in 3 - 5 working days  Usually delivered in 3 - 5 working days
Details
The Destination for Medical Supplies.
Call us on 020 7501 0593
Docs